How do folding doors withstand high wind loads?
Wind load resilience in wide-span Aluminium Slide and Fold Doors depends directly on the structural moment of inertia (Ix value) of the vertical interlocking stiles. High-rise and coastal installations require extruded 6063-T6 profiles with multi-cavity internal ribbing, wall thicknesses between 2.0mm and 3.0mm, and heavy-duty top/bottom guide pins engineered to prevent deflection under positive and negative pressures exceeding 3000 Pa.